Railway Power Supply for Electrification and Rolling Stock
Railway power supply: 24–110 V DC nominal, EN 50155 ranges, EN 61373 vibration, three input sources on one converter, with railway signalling power supply and railway battery charger builds

A vehicle sees three different supply conditions in one duty cycle: pantograph or third shoe at full voltage, a battery bus that sags during starting, and a dead section. A rolling stock converter has to hold its output through all three.
What a railway power supply on rolling stock has to survive
The supply range that matters is not the nominal voltage. Under EN 50155 the intermediate circuit on a 750 V or 1500 V system is specified as 0.6–1.25 × nominal for the low-voltage bus, and the converter has to ride through a 10 ms interruption without dropping the output. On a battery bus, the voltage sags to 0.6 × nominal while a compressor starts.
A railway power supply that only works at nominal voltage will pass a bench test and fail on the vehicle. We test the quoted unit across the full EN 50155 range, including the interruption, and the test report ships with the unit.
Standards, and what each covers
| Standard | What it covers |
|---|---|
| EN 50155 | Electronic equipment on rolling stock — supply range, interruption class, temperature class |
| EN 61373 | Shock and vibration testing for equipment mounted on the vehicle body |
| EN 50121-3-2 | EMC for apparatus on rolling stock, including the traction environment |
| EN 45545-2 | Fire behaviour of materials, by hazard level |
We quote the class numbers, not the standard name. A unit described only as "EN 50155 compliant", with no class list, is not a specification.
Specifications
| Parameter | Value |
|---|---|
| Nominal bus | 24 / 36 / 48 / 72 / 96 / 110 V DC |
| Input range | 0.6–1.25 × nominal, 10 ms ride-through |
| Output | 24 / 48 / 110 V DC, 150–3000 W |
| Temperature class | OT1 to OT4, set by mounting location |
| Vibration / shock | EN 61373 cat. 1 class B |
| EMC | EN 50121-3-2 |
| Fire behaviour | EN 45545-2 HL2 / HL3 on request |
| Isolation | 1500 V DC in to out, 2500 V AC to case |
| Cooling | Conduction for OT3/OT4, fan option for OT1 |
Traction power supply and the auxiliary bus
The traction power supply itself is a separate product from the auxiliary converter, but they share the same input conditions and the same standards. Where a vehicle needs both, we quote them as one system with a shared battery bus and a single set of protection settings, which is cheaper to test and simpler to maintain than two independent units.
For a vehicle that also needs backup on the auxiliary bus, the answer is a DC system rather than a bare converter: the converter charges, the battery holds the load through gaps, and the distribution feeds the cab and the doors.
Where it goes on the vehicle
- Central power — the auxiliary converter feeding the low-voltage bus.
- Battery charging — float and boost on the vehicle battery string.
- Communication and signalling — the protected, filtered feeds.
- Infotainment and passenger systems — isolated outputs so a fault does not propagate.
- Door and brake control — the loads that must not drop out during a dead section.
What we would fit on the vehicle
| Section | Configuration | Notes |
|---|---|---|
| Input | Battery bus, 0.6–1.25 × nominal, class S2 | |
| Conversion | dc/dc converter, EN 50155 class sheet supplied | |
| Backup | Battery ride-through for gaps and dead sections | |
| Distribution | dc panel with graded feeders to cab and doors | |
| Monitoring | Bus voltage, converter status, battery health |
Mounting decides the temperature class
- Under-floor or roof: OT3 or OT4, conduction cooling, sealed
- In-cabinet: OT1, forced air acceptable
- Next to a traction motor or brake resistor: assume OT4 and measure the local temperature before quoting
- Vibration testing is on the assembled unit, not the bare board
Harness routing and noise
Keep the converter input harness short and direct, and route it away from the traction and door-control wiring. Long input leads add inductance that shows up as a voltage dip whenever a contactor pulls in, and that dip is what trips an under-voltage lockout. Earth the case at the point the drawing specifies, not wherever a bolt is convenient.
Send us the numbers
Send the nominal bus voltage, the mounting location and the interruption class. You get the converter, the class sheet and the harness routing note.
Standards referenced on this page
- EN 50155 — Electronic equipment used on rolling stock
- EN 45545-2 — Fire behaviour of materials on railway vehicles
Frequently asked questions
QWhy is vibration the hard part rather than temperature?
Because temperature can be measured and derated for, while vibration fatigue is cumulative and invisible until something opens. Solder joints, connector pins and heavy components on long leads fail after months of service. A unit that passes a bench test has not passed a vibration test, and the category depends on the mounting position — body, bogie and cabinet are different environments.
QWhat is the EN 61373 category?
The vibration and shock category for railway rolling stock equipment, defined by mounting position in EN 61373 and referenced by EN 50155. Body-mounted, bogie-mounted and axle-mounted equipment are tested to different severities. A compliance claim that does not state the category and the mounting position has not told you what was actually tested.
QCan I use an industrial power supply in a trackside cabinet?
Often yes, and frequently it is the right choice. Trackside locations in a technical room are much closer to an industrial environment than to rolling stock. The decision points are the supply range on the feeder, the ambient inside the cabinet, and whether the client's specification names EN 50155. If it does, no amount of industrial build quality will substitute for the class.
QHow do I stop a reset during a supply interruption?
Specify the interruption class — S1, S2 or S3 — together with the duration in milliseconds, and make the converter's hold-up meet it. Most resets on rolling stock are not caused by the supply going out of range; they are caused by a brief interruption that nobody specified and no hold-up was sized for. One line in the specification prevents most of them.
QWhat should I demand before I accept a converter?
A type test report naming the tested order code and the standard revision, the conformal coating process certificate, the mounting drawing and the pinout in an editable format, and a per-batch vibration record where the category is above body mount. A family declaration is not evidence, and any operator with a qualification department will reject it.